NightmatIQ Plus

NightmatIQ Plus

Steinel Vertrieb GmbH

Basic Information

Product ID 1DCE
Version 0840
Category Sensor
Subcategory Ambient Light Sensor
Price (EUR) ~50€
Mesh Features Relay, Proxy, Friend

Notes

Ambient light sensor containing one relay to switch loads up to 1000 W. Can be installed outdoors.

Elements & Models

Element 0

Main control element with relay switching and scene management

0x0000 Configuration Server

Manages device configuration such as adding/removing keys, publishing settings, and subscription lists. Present on every mesh node.

0x0002 Health Server

Reports device health status and performs self-tests. Allows monitoring of node functionality and diagnostics.

0x1000 Generic OnOff Server

Controls binary states (on/off) such as switches, relays, or simple lighting control.

Note: Turns on/off connected light (relay)

0x1002 Generic Level Server

Controls continuous values (0-100%) like dimmer levels, fan speeds, or motor positions.

Note: Controls brightness level (0% = off, ≥1% = on)

0x1004 Generic Default Transition Time Server

Sets default timing for smooth transitions between states (e.g., fade duration for lights).

0x1006 Generic Power OnOff Server

Controls device behavior when power is restored after power loss (off, on, or restore previous state).

Note: Untested - should set default power-state after power loss/recover

0x1007 Generic Power OnOff Setup Server

Configures power-on behavior settings for devices with persistent memory.

0x1200 Time Server

Provides current time information and timezone data to the network.

0x1201 Time Setup Server

Configures time settings including timezone, TAI-UTC offset, and time authority.

0x1203 Scene Server

Stores and recalls predefined scenes with multiple device states (e.g., lighting moods).

Note: Recall a stored scene

0x1204 Scene Setup Server

Configures and manages scene definitions, allowing creation of custom lighting scenarios.

Note: Store scenes

0x1206 Scheduler Server

Schedules automatic actions based on time, date, or recurring patterns.

0x1207 Scheduler Setup Server

Configures scheduler entries with time triggers and associated actions.

0x1300 Light Lightness Server

Controls the brightness/intensity of lighting devices with smooth dimming capabilities.

0x1301 Light Lightness Setup Server

Configures lightness parameters like minimum/maximum levels and fade curves.

0x0563100B Steinel Vertrieb GmbH

Custom model implementation specific to this vendor. Provides proprietary functionality beyond standard Bluetooth® mesh models.

0x0563100D Steinel Vertrieb GmbH

Custom model implementation specific to this vendor. Provides proprietary functionality beyond standard Bluetooth® mesh models.

Element 1

Light control element with ambient light detection publishing

0x1000 Generic OnOff Server

Controls binary states (on/off) such as switches, relays, or simple lighting control.

Note: Turns on/off connected light (relay)

0x1001 Generic OnOff Client

Sends on/off commands to Generic OnOff Servers, such as wall switches or app controls.

Note: Untested - probably publishes whether it is dark or bright

0x1205 Scene Client

Sends scene recall and control commands to Scene Servers.

0x130F Light LC Server

Provides automated lighting control based on occupancy, ambient light, and time schedules.

0x1310 Light LC Setup Server

Configures Light LC parameters like sensor thresholds, timeouts, and control algorithms.

0x05631001 Steinel Vertrieb GmbH

Custom model implementation specific to this vendor. Provides proprietary functionality beyond standard Bluetooth® mesh models.

0x05631006 Steinel Vertrieb GmbH

Custom model implementation specific to this vendor. Provides proprietary functionality beyond standard Bluetooth® mesh models.

0x05631004 Steinel Vertrieb GmbH

Custom model implementation specific to this vendor. Provides proprietary functionality beyond standard Bluetooth® mesh models.

0x05631005 Steinel Vertrieb GmbH

Custom model implementation specific to this vendor. Provides proprietary functionality beyond standard Bluetooth® mesh models.

Element 3

Ambient light sensor element

0x1100 Sensor Server

Reports sensor data like temperature, humidity, motion, or light levels to the network.

Note: Present Ambient Light Level (e.g. 455.72 medium bright room)

0x1101 Sensor Setup Server

Configures sensor parameters like sampling rates, thresholds, and reporting intervals.